Update a specific usage data entry by its ID. Updates to the meter and identifiers will also be reflected.
ID of the usage data entry to update.
Serializer for updating MeterSiteUsageData instances via the API.
Start date for the meter site usage data entry.
End date for the meter site usage data entry. If not available or not applicable, this is set to the start date by default.
J - JBtu - BtuMMBtu - MmbtukJ - KjMJ - MjGJ - GjTJ - Tjthm (EC) - Therm Ecthm (US) - Therm Usthm (UK) - Therm UkDth (EC) - Dth EcDth (US) - Dth UsDth (UK) - Dth UkCal - CalkCal - KcalMCal - Mcalerg - ErgkVA - KvaWh - WHkWh - KWHMWh - MWHGWh - GWHton hours - Ton HoursW - WKW - KwMW - MwGW - GwL - LkL - KlML - Mlcubic ft - Cubic Ftcubic yd - Cubic Ydcubic m - Cubic MMMCF - MmcfMCF - McfHCF - HcfCF - CfCCF - Ccfgal (UK) - Gal Ukgal (US) - Gal Us100 gal (US) - Hundred Gal Us100 gal (UK) - Hundred Gal Ukkgal (US) - Kgal Uskgal (UK) - Kgal UkMgal (US) - Million Gal UsMgal (UK) - Million Gal Ukteu - Teubbl - Bblmbbl - Mbblkg - Kgoz t - Oz Tg - Glb - Lbmlb - Mlbtons (US) - Tonssh ton - Sh Tonmetric ton - Metric Tontonne - Tonnelong tn - Long Tnkm - Kmmi - Mim - Mcm - Cmmm - Mmnm - Nmyd - Ydft - Ftin - InJ, Btu, MMBtu, kJ, MJ, GJ, TJ, thm (EC), thm (US), thm (UK), Dth (EC), Dth (US), Dth (UK), Cal, kCal, MCal, erg, kVA, Wh, kWh, MWh, GWh, ton hours, W, KW, MW, GW, L, kL, ML, cubic ft, cubic yd, cubic m, MMCF, MCF, HCF, CF, CCF, gal (UK), gal (US), 100 gal (US), 100 gal (UK), kgal (US), kgal (UK), Mgal (US), Mgal (UK), teu, bbl, mbbl, kg, oz t, g, lb, mlb, tons (US), sh ton, metric ton, tonne, long tn, km, mi, m, cm, mm, nm, yd, ft, in Indicates if the meter site usage data entry is subtracted in aggregation (to be used when meter is used to measure what needs to be deducted in the case of landlord - tenant calculations).
Indicates if the usage data is estimated by the utility company.
Indicates if the usage data is implied by the tenant usage and the raw usage. For more information on how this differs from estimation, see the Nectar methodology.
[ELECTRICITY, GAS, WATER, DISTRICT] Tariff code or description associated with the usage.
[ELECTRICITY, GAS] Name of the supplier. Only applies to electricity and gas meters.
Serializer for MeterSiteUsageData.
External serializer wraps around the helper serializer to provide a more user-friendly interface.
UUID of the meter site usage data entry.
Timestamp when the meter site usage data entry was created.
Start date for the meter site usage data entry.
End date for the meter site usage data entry. If not available or not applicable, this is set to the start date by default.
Usage amount extracted from billing data. For solar data, this is the kWh produced.
Units for usage, as specified in the document
J - JBtu - BtuMMBtu - MmbtukJ - KjMJ - MjGJ - GjTJ - Tjthm (EC) - Therm Ecthm (US) - Therm Usthm (UK) - Therm UkDth (EC) - Dth EcDth (US) - Dth UsDth (UK) - Dth UkCal - CalkCal - KcalMCal - Mcalerg - ErgkVA - KvaWh - WHkWh - KWHMWh - MWHGWh - GWHton hours - Ton HoursW - WKW - KwMW - MwGW - GwL - LkL - KlML - Mlcubic ft - Cubic Ftcubic yd - Cubic Ydcubic m - Cubic MMMCF - MmcfMCF - McfHCF - HcfCF - CfCCF - Ccfgal (UK) - Gal Ukgal (US) - Gal Us100 gal (US) - Hundred Gal Us100 gal (UK) - Hundred Gal Ukkgal (US) - Kgal Uskgal (UK) - Kgal UkMgal (US) - Million Gal UsMgal (UK) - Million Gal Ukteu - Teubbl - Bblmbbl - Mbblkg - Kgoz t - Oz Tg - Glb - Lbmlb - Mlbtons (US) - Tonssh ton - Sh Tonmetric ton - Metric Tontonne - Tonnelong tn - Long Tnkm - Kmmi - Mim - Mcm - Cmmm - Mmnm - Nmyd - Ydft - Ftin - InJ, Btu, MMBtu, kJ, MJ, GJ, TJ, thm (EC), thm (US), thm (UK), Dth (EC), Dth (US), Dth (UK), Cal, kCal, MCal, erg, kVA, Wh, kWh, MWh, GWh, ton hours, W, KW, MW, GW, L, kL, ML, cubic ft, cubic yd, cubic m, MMCF, MCF, HCF, CF, CCF, gal (UK), gal (US), 100 gal (US), 100 gal (UK), kgal (US), kgal (UK), Mgal (US), Mgal (UK), teu, bbl, mbbl, kg, oz t, g, lb, mlb, tons (US), sh ton, metric ton, tonne, long tn, km, mi, m, cm, mm, nm, yd, ft, in [ELECTRICITY] Array of time-of-use breakdown entries when usage is split by TOU periods. Each entry contains timeOfUse category, usage amount, units, and optional description/dates.
Address of the service location associated with the usage data.
Id of the matching meter associated with the usage data. For uploaded documents, field may be empty if no matching meter is found.
Site matched with the usage data.
Identifiers associated with the meter.
Type of data source (utility) for the usage data entry.
ELECTRICITY - ElectricityGAS - GasWATER - WaterDISTRICT - DistrictWASTE - WasteFUEL - FuelMISC - MiscREFRIGERANT - RefrigerantSOLAR - SolarTELECOM - TelecomELECTRICITY, GAS, WATER, DISTRICT, WASTE, FUEL, MISC, REFRIGERANT, SOLAR, TELECOM [ELECTRICITY] DEPRECATED: Time of use associated with the electricity usage data entry. Use timeOfUseBreakdown field instead for TOU information.
PEAK - PeakOFF_PEAK - Off PeakSHOULDER_MIDPEAK - Shoulder MidpeakNIGHT_TIME - Night TimeDAY_TIME - Day TimeSUPER_OFF_PEAK - Super Off PeakCRITICAL_PEAK - Critical PeakWEEKDAY - WeekdayWEEKEND - WeekendOTHER - OtherPEAK, OFF_PEAK, SHOULDER_MIDPEAK, NIGHT_TIME, DAY_TIME, SUPER_OFF_PEAK, CRITICAL_PEAK, WEEKDAY, WEEKEND, OTHER [ELECTRICITY] Indicates whether the meter is tracking electricity imports from the grid, exports to the grid, or onsite generation.
EXPORT - ExportIMPORT - ImportGENERATION - GenerationEXPORT, IMPORT, GENERATION [WATER] Type of water used.
POTABLE_WATER - Potable WaterWELL_WATER - Well WaterMUNICIPAL_WATER - Municipal WaterWASTE_WATER - Waste WaterPOTABLE_WATER, WELL_WATER, MUNICIPAL_WATER, WASTE_WATER [WATER] Indicates if the meter type is 'HIGH' or 'LOW'.
HIGH - HighLOW - LowHIGH, LOW [GAS] Type of gas used.
NATURAL_GAS - Natural GasNATURAL_GAS [FUEL] Type of fuel used, with predefined choices.
ANTHRACITE_COAL - Anthracite CoalBITUMINOUS_COAL - Bituminous CoalSUB_BITUMINOUS_COAL - Sub Bituminous CoalLIGNITE_COAL - Lignite CoalMIXED_COMMERCIAL_SECTOR - Mixed Commercial SectorMIXED_ELECTRIC_POWER_SECTOR - Mixed Electric Power SectorMIXED_INDUSTRIAL_COKING - Mixed Industrial CokingMIXED_INDUSTRIAL_SECTOR - Mixed Industrial SectorCOAL_COKE - Coal CokeMUNICIPAL_SOLID_WASTE - Municipal Solid WastePETROLEUM_COKE_SOLID - Petroleum Coke SolidPLASTICS - PlasticsTIRES - TiresAGRICULTURAL_BYPRODUCTS - Agricultural ByproductsPEAT - PeatSOLID_BYPRODUCTS - Solid ByproductsWOOD_AND_WOOD_RESIDUALS - Wood And Wood ResidualsNATURAL_GAS - Natural GasBLAST_FURNACE_GAS - Blast Furnace GasCOKE_OVEN_GAS - Coke Oven GasFUEL_GAS - Fuel GasPROPANE_GAS - Propane GasLANDFILL_GAS - Landfill GasOTHER_BIOMASS_GASES - Other Biomass GasesASPHALT_AND_ROAD_OIL - Asphalt And Road OilBUTANE - ButaneBUTYLENE - ButyleneCRUDE_OIL - Crude OilDISTILLATE_FUEL_OIL_NO_1 - Distillate Fuel Oil No 1DISTILLATE_FUEL_OIL_NO_2 - Distillate Fuel Oil No 2DISTILLATE_FUEL_OIL_NO_4 - Distillate Fuel Oil No 4ETHANE - EthaneETHYLENE - EthyleneHEAVY_GAS_OILS - Heavy Gas OilsISOBUTANE - IsobutaneISOBUTYLENE - IsobutyleneKEROSENE - KeroseneLIQUEFIED_PETROLEUM_GASES_LPG - Liquefied Petroleum Gases LpgCOMPRESSED_NATURAL_GAS_CNG - Compressed Natural Gas CngLUBRICANTS - LubricantsMOTOR_GASOLINE - Motor GasolineNAPHTHA_LESS_THAN_401_DEG_F - Naphtha Less Than 401 Deg FNATURAL_GASOLINE - Natural GasolineOTHER_OIL_MORE_THAN_401_DEG_F - Other Oil More Than 401 Deg FPENTANES_PLUS - Pentanes PlusPETROCHEMICAL_FEEDSTOCKS - Petrochemical FeedstocksPROPYLENE - PropyleneRESIDUAL_FUEL_OIL_NO_5 - Residual Fuel Oil No 5RESIDUAL_FUEL_OIL_NO_6 - Residual Fuel Oil No 6SPECIAL_NAPHTHA - Special NaphthaUNFINISHED_OILS - Unfinished OilsUSED_OIL - Used OilBIODIESEL_100_PERCENT - Biodiesel 100 PercentBIODIESEL_BLEND - Biodiesel BlendETHANOL_BLENDED_GASOLINE - Ethanol Blended GasolineETHANOL_100_PERCENT - Ethanol 100 PercentRENDERED_ANIMAL_FAT - Rendered Animal FatVEGETABLE_OIL - Vegetable OilNORTH_AMERICAN_SOFTWOOD - North American SoftwoodNORTH_AMERICAN_HARDWOOD - North American HardwoodBAGASSE - BagasseBAMBOO - BambooSTRAW - StrawANTHRACITE_COAL, BITUMINOUS_COAL, SUB_BITUMINOUS_COAL, LIGNITE_COAL, MIXED_COMMERCIAL_SECTOR, MIXED_ELECTRIC_POWER_SECTOR, MIXED_INDUSTRIAL_COKING, MIXED_INDUSTRIAL_SECTOR, COAL_COKE, MUNICIPAL_SOLID_WASTE, PETROLEUM_COKE_SOLID, PLASTICS, TIRES, AGRICULTURAL_BYPRODUCTS, PEAT, SOLID_BYPRODUCTS, WOOD_AND_WOOD_RESIDUALS, NATURAL_GAS, BLAST_FURNACE_GAS, COKE_OVEN_GAS, FUEL_GAS, PROPANE_GAS, LANDFILL_GAS, OTHER_BIOMASS_GASES, ASPHALT_AND_ROAD_OIL, BUTANE, BUTYLENE, CRUDE_OIL, DISTILLATE_FUEL_OIL_NO_1, DISTILLATE_FUEL_OIL_NO_2, DISTILLATE_FUEL_OIL_NO_4, ETHANE, ETHYLENE, HEAVY_GAS_OILS, ISOBUTANE, ISOBUTYLENE, KEROSENE, LIQUEFIED_PETROLEUM_GASES_LPG, COMPRESSED_NATURAL_GAS_CNG, LUBRICANTS, MOTOR_GASOLINE, NAPHTHA_LESS_THAN_401_DEG_F, NATURAL_GASOLINE, OTHER_OIL_MORE_THAN_401_DEG_F, PENTANES_PLUS, PETROCHEMICAL_FEEDSTOCKS, PROPYLENE, RESIDUAL_FUEL_OIL_NO_5, RESIDUAL_FUEL_OIL_NO_6, SPECIAL_NAPHTHA, UNFINISHED_OILS, USED_OIL, BIODIESEL_100_PERCENT, BIODIESEL_BLEND, ETHANOL_BLENDED_GASOLINE, ETHANOL_100_PERCENT, RENDERED_ANIMAL_FAT, VEGETABLE_OIL, NORTH_AMERICAN_SOFTWOOD, NORTH_AMERICAN_HARDWOOD, BAGASSE, BAMBOO, STRAW [DISTRICT] Type of district used, either HEATING or COOLING.
HEATING - HeatingCOOLING - CoolingHEATING, COOLING [DISTRICT] Type of heating or cooling medium used, e.g. STEAM, HOT_WATER, etc.
HOT_WATER - Hot WaterSTEAM - SteamHOT_OIL - Hot OilCHILLED_WATER - Chilled WaterHOT_WATER, STEAM, HOT_OIL, CHILLED_WATER [WASTE] Description of the waste line item. E.g. OCC, Plastic bottles, etc.
[WASTE] Type of waste, e.g. OCC, Plastic bottles, etc. The waste type config can be configured on the Nectar platform.
[WASTE] Stream of waste, e.g. OCC, Plastic bottles, etc. The waste stream config can be configured on the Nectar platform.
[REFRIGERANT] Type of refrigerant used.
R11 - R11R12 - R12R22 - R22R123 - R123R124 - R124R134A - R134AR401A - R401AR401B - R401BR402A - R402AR402B - R402BR403A - R403AR403B - R403BR404A - R404AR405A - R405AR406A - R406AR407A - R407AR407B - R407BR407C - R407CR407D - R407DR407F - R407FR408A - R408AR409A - R409AR409B - R409BR410A - R410AR410B - R410BR411A - R411AR411B - R411BR412A - R412AR413A - R413AR413B - R413BR414A - R414AR414B - R414BR415A - R415AR415B - R415BR416A - R416AR417A - R417AR417B - R417BR417C - R417CR418A - R418AR419A - R419AR419B - R419BR420A - R420AR420B - R420BR421A - R421AR421B - R421BR421C - R421CR422A - R422AR422B - R422BR422C - R422CR422D - R422DR422E - R422ER423A - R423AR423B - R423BR424A - R424AR424B - R424BR425A - R425AR426A - R426AR426B - R426BR426C - R426CR427A - R427AR427B - R427BR427C - R427CR428A - R428AR428B - R428BR429A - R429AR429B - R429BR430A - R430AR430B - R430BR431A - R431AR431B - R431BR432A - R432AR432B - R432BR433A - R433AR433B - R433BR433C - R433CR433D - R433DR434A - R434AR434B - R434BR435A - R435AR435B - R435BR436A - R436AR436B - R436BR437A - R437AR437B - R437BR438A - R438AR438B - R438BR444B - R444BR445A - R445AR447A - R447AR448A - R448AR448B - R448BR449A - R449AR449B - R449BR450A - R450AR450B - R450BR451A - R451AR451B - R451BR452A - R452AR452B - R452BR453A - R453AR454A - R454AR454B - R454BR454C - R454CR455A - R455AR456A - R456AR459A - R459AR460A - R460AR461A - R461AR462A - R462AR463A - R463AR464A - R464AR465A - R465AR115 - R115R116 - R116R12B1 - R12B1R13 - R13R13B1 - R13B1R13I1 - R13I1R14 - R14R14e - R14ER21 - R21R23 - R23R30 - R30R31 - R31R40 - R40R41 - R41R50 - R50R113 - R113R114 - R114R125 - R125R141B - R141BR142B - R142BR143A - R143AR152A - R152AR170 - R170R218 - R218R290 - R290R318 - R318R600 - R600R600A - R600AR717 - R717R744 - R744R508B - R508BR1270 - R1270R32 - R32R161 - R161R227EA - R227EaR236CB - R236CbR236EA - R236EaR236FA - R236FaR245CA - R245CaR245FA - R245FaR414C - R414CR415C - R415CR416B - R416BR123A - R123AR123B - R123BR365MFC - R365MfcR4310 - R4310R127C - R127CR12A - R12AR22A - R22AR502A - R502AR601A - R601AR11, R12, R22, R123, R124, R134A, R401A, R401B, R402A, R402B, R403A, R403B, R404A, R405A, R406A, R407A, R407B, R407C, R407D, R407F, R408A, R409A, R409B, R410A, R410B, R411A, R411B, R412A, R413A, R413B, R414A, R414B, R415A, R415B, R416A, R417A, R417B, R417C, R418A, R419A, R419B, R420A, R420B, R421A, R421B, R421C, R422A, R422B, R422C, R422D, R422E, R423A, R423B, R424A, R424B, R425A, R426A, R426B, R426C, R427A, R427B, R427C, R428A, R428B, R429A, R429B, R430A, R430B, R431A, R431B, R432A, R432B, R433A, R433B, R433C, R433D, R434A, R434B, R435A, R435B, R436A, R436B, R437A, R437B, R438A, R438B, R444B, R445A, R447A, R448A, R448B, R449A, R449B, R450A, R450B, R451A, R451B, R452A, R452B, R453A, R454A, R454B, R454C, R455A, R456A, R459A, R460A, R461A, R462A, R463A, R464A, R465A, R115, R116, R12B1, R13, R13B1, R13I1, R14, R14e, R21, R23, R30, R31, R40, R41, R50, R113, R114, R125, R141B, R142B, R143A, R152A, R170, R218, R290, R318, R600, R600A, R717, R744, R508B, R1270, R32, R161, R227EA, R236CB, R236EA, R236FA, R245CA, R245FA, R414C, R415C, R416B, R123A, R123B, R365MFC, R4310, R127C, R12A, R22A, R502A, R601A Additional fields for the usage data. For information on adding custom fields to the Nectar schema get in touch with our team.
Whether the meter is tracked.
Address of the meter.
Document associated with the usage data.
Timestamp when the meter site usage data entry was last updated.
Indicates if the usage data is estimated by the utility company.
Indicates if the usage data is implied by the tenant usage and the raw usage. For more information on how this differs from estimation, see the Nectar methodology.
Current meter reading.
^-?\d{0,10}(?:\.\d{0,10})?$Previous meter reading.
^-?\d{0,10}(?:\.\d{0,10})?$Multiplier applied to the meter reading.
^-?\d{0,10}(?:\.\d{0,10})?$Description of the multiplier applied to the meter reading. E.g. conversion factor, pressure adjustment, etc.
Second multiplier applied to the meter reading.
^-?\d{0,10}(?:\.\d{0,10})?$Description of the second multiplier applied to the meter reading. E.g. conversion factor, pressure adjustment, etc.
[ELECTRICITY] Fraction of energy sourced from renewable resources (0 to 1). This field is populated from the utility bill or set by a user.
^-?\d{0,5}(?:\.\d{0,5})?$[ELECTRICITY] Total kWh of electricity generated from solar on-site.
^-?\d{0,10}(?:\.\d{0,10})?$[ELECTRICITY] Total kWh of electricity imported from the grid, only applicable if the meter is not tracking imports.
^-?\d{0,10}(?:\.\d{0,10})?$[ELECTRICITY] Total kWh of electricity exported to the grid, only applicable if the meter is not tracking exports.
^-?\d{0,10}(?:\.\d{0,10})?$Indicates if the meter site usage data entry is subtracted in aggregation (to be used when meter is used to measure what needs to be deducted in the case of landlord - tenant calculations).
[ELECTRICITY, GAS, WATER, DISTRICT] Tariff code or description associated with the usage.
[ELECTRICITY] Total billed kW, meter level. Only applies to electricity meters. If billed demand is not available or allocatable across multiple meters, this field is set to 0.
^-?\d{0,10}(?:\.\d{0,10})?$[ELECTRICITY, GAS] Name of the supplier. Only applies to electricity and gas meters.
[ELECTRICITY, GAS] Name of the local delivery utility company. Only applies to electricity and gas meters.
Country associated with the meter site usage data entry.